# FALL OF ROOF OR BACK
> MSHA accident `220062920037` · 10/16/2006 · Marfork Coal Company Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:** Marfork Coal Company Inc
- **Mine:** [4608913](https://api.ai-analytics.org/mine/4608913)
## Narrative

Fall occurred in the track entry at spad #112. Fall was 20'L x 20'W x 8'H. Intersection was bolted with 4' resin bolts. Fall was approx 3400' from face. Men were evacuated and area has been timbered. off. A cleanup plan has been posted and is being followed. There were no injuries.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*