# FALL OF ROOF OR BACK
> MSHA accident `220062960009` · 10/18/2006 · American Energy Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** American Energy Corporation
- **Mine:** [3301070](https://api.ai-analytics.org/mine/3301070)
## Narrative

A roof fall occurred on the South Mains ""A"" beltline at 69 x-cut.  The fall is approx. 40 feet long by 18' wide and 9' high.  Area was bolted with 8' Install 3 bolts and resioned.  Other support that were installed were 4"" H-beams and cribs.  Cause of this fall was deterioration of the main roof due to weathering.

---