# HOISTING
> MSHA accident `220062960019` · 10/16/2006 · Peabody Midwest Mining, LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Peabody Energy Corporation
- **Operator:** Peabody Midwest Mining, LLC
- **Mine:** [1202010](https://api.ai-analytics.org/mine/1202010)
## Narrative

The elevator at the Hart street portal failed to operate.  The elevator would not move up or down in the shaft.  The cause of the malfunction was traced to a faulty elevator brake rope switch.  The switch was replaced and the elevator was returned to service.

---