A fall was discovered in the No.1 Return Entry of West Mains at Survey Station 224. The fall measured approximately 20' long x 20' wide x 10' high and had been supported with 5' fully grouted resin roof bolts. There were no injuries or equipment involved. Ventilation was not affected. The fall will not be cleaned up.