A roof fall occurred at 9:32 pm on Tuesday October 24, 2006 in the 2-east main belt entry. The roof fall is located between spads 10054 and 10068 and is approx 20' wide X 6' high and 70' long. This area was supported with 6' resin bolts at the time of the roof fall.