A roof fall occurred in the 2 Left Section. It occurred in the No. 4 Entry, 1 X-cut inby Station #254. Fall was approximately 6' - 8' high, 19' wide, 65' long. Fall caught high voltage cable along with the required lifeline. Area was timbered and dangered off. Escapeway was re-routed along with the required lifeline.