An unplanned roof fall occurred in the #4 entry of the 2 Left Rooms 2 x-cuts inby survey station #420 and passed through x-cut to the #3 entry. Roof fall was approximately 55' long, 18.5' wide, and 4' plus high. Fall did change our course of travel in the return. Area was dangered and timbered off.