A fall of roof occurred in the 1A Panel in the # 5 Entry, between x-cut 31 and 32. The fall was approx 35ft long x 19ft wide x 8ft high. The distance from the fall to the face was approx 980ft. A hidden slip with water was determined to be the cause of the fall.