← MSHA accidents

ELECTRICAL

220070050033 · 01/03/2007 · Eastern Consolidated Energy Inc

Details

Degree of injury
DAYS AWAY FROM WORK ONLY
Classification
ELECTRICAL
Accident type
Contact with electrical current
Occupation
Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss
Activity
Electrical maintenance
Injury source
ELECTRICAL APPARATUS,NEC
Nature of injury
ELECTRIC BURN-CNTACT BURN
Body part
HAND (NOT WRIST OR FINGERS)
Days lost
2
Mine experience
0.31 years

Operator

Controller (parent)
Consolidated Energy Inc
Operator
Eastern Consolidated Energy Inc
Mine
1516761

Narrative

Employee was changing batteries on the 828 ram car. The energy source was under load. A phase to ground fault occurred. The employee received 2nd degree burns on his right hand.

Source

Authoritative
MSHA Open Government Data
Machine