Workers were preparing to remove the roller bearing from the intermediate symetro gear using a tri-jaw hydraulic gear puller. After securing the puller and applying the pressure, they started warming up the roller so it would begin loosening the bearing. On a sudden release of the bearing, one of the puller jaws slung out impacting the worker's left hand and chest.