← MSHA accidents

HOISTING

220070120058 · 12/29/2006 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
4601968

Narrative

The Kuhntown elevator stopped 90-100' below the top landing. Breaker was re-set and ran in inspection mode to get 16 employees on elevator off. Contact nips were replaced and elevator tested several times and cleared for normal operations by MSHA.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown