A roof fall occured in the 6 south panel, #6 entry, starting at crosscut #24 and ending at crosscut #25. The fall measured approximately 60'x 19'x 5'-9'. The area was supported with 5' fully grouted bolts and the intersections have 5 additional 9' mega bolts. An undetected slip was determined to be the cause of the fall.