An unplanned roof fall occurred in the 2 left #1 room set-up 1 x-cut inby survey station #288. Fall was approximately 30 feet long, 20 feet wide, 4 feet plus high. Did not affect any ventilation but did change the route of travel in the air course run. Area was timbered and dangered off.