A roof fall occurred on 2/7/07 at 7:55 AM at survey station 2 + 80 entry 1 5rms unit. Fall was in a four way intersection that had been mined March of 2005. Area had been bolted with 6 & 8' full resin pins. No injury occurred but 300 feet of cable was lost. Area around the fall was dangered off adn resupported. There are no plans to clean up the fall.