← MSHA accidents

FALL OF ROOF OR BACK

220070400045 · 02/07/2007 · ICG-Illinois, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
International Coal Group Inc (ICG)
Operator
ICG-Illinois, LLC
Mine
1102664

Narrative

A roof fall occurred on 2/7/07 at 7:55 AM at survey station 2 + 80 entry 1 5rms unit. Fall was in a four way intersection that had been mined March of 2005. Area had been bolted with 6 & 8' full resin pins. No injury occurred but 300 feet of cable was lost. Area around the fall was dangered off adn resupported. There are no plans to clean up the fall.

Source

Authoritative
MSHA Open Government Data
Machine