On the morning of February 8th, 2007 a small rock burst occurred on the 3700 level in the hanging wall, about halfway between the 230 raise and the 244 raise at track level. The outburst disrupted about a 40' length of hanging wall. It also knocked down & disrupted compressed air & water lines. This interupted mining in the 244 & 291 stopes. No one injured or ventilation impaired.