Location: Old works in return; entry No.3, spad no.2040. Distance from active face: 2,000', Airway: neutral. Size: L-20', W-20', H-5'; 48"" resin fully grouted, no cribs or timbers installed prior to fall. Strata: shale, no coal rider seam present. All entrances to fall breakered off, area will not be rehabilitated.