Unintentional roof fall discovered at 7:40AM. Fall measured approximately 20'L X 20'W X 10'H. Intersection was previously supported with 6' full grout resin bolts and 10' long cable bolts. Area was mined the week of 03/15/2007. At the time of this report, the 4 approaches to the fall will be cribbed off.