On 3/6/07, an unintentional roof fall occurred on the 2nd W. sub-main off the 3rd south in #8 entry at cross cut #23. this roof fall was supported with 6 and 10' point anchor roof bolts the roof fall measured 20' long x 18' wide x 10' high. the roof fall will not be cleaned up.