The crew noticed that their belts went down. Upon investigation they saw that the roof was working and left the area. When they came back they found an intersection containing the lo-belt drive had caved. The area was bolted with 42 inch fully grouted resin bolts. The fall is approximately 20 ft x 60 ft x 4-6 ft high. The area has been cribbed and dangered off.