An unintentional roof fall occurred in the #4 entry at the #67 crosscut on the #3 belt. The fall measured approximately 20' wide x 6' high x 40' long. Area was supported by 4' fully grouted bolts. No injuries, no equipment caught & ventilation was not interrupted.