← MSHA accidents

FALL OF ROOF OR BACK

220071010035 · 04/03/2007 · CONSOL of Kentucky Inc.

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
CONSOL of Kentucky Inc.
Mine
4608892

Narrative

An unintentional roof fall was discoverd in the #1 entry (return) one break outby spad #816. Size of fall was estimated to be 5'H X 18'-20'W X 20'L. Fall will not be cleaned up. No injuries occurred, no equipment caught and ventilation was not interrupted. Area had been bolted with 4' fully grouted resin bolts. Fall will not be cleaned up.