A roof fall was discovered on top of the overcast. The fall was approximately 4' thick x 12' wide x 18' long. The fall damaged the overcast and was allowing return air from 003 section to mix with intake air going to 001 section. The fall was 1 x-cut over from spad #382. Both sections were idled immediately upon discovering this accident.