A roof fall occurred in the 1 Main East in #4 entry in the intersection of cross-cut # 56 measuring 18ft. x 18ft. x 6ft. The area was supported with 6ft. tension rebar bolts. An undetected slip was determined to be the cause of the fall. This area was mined in August 2005.