FALL OF ROOF OR BACK

220071160012 · 04/21/2007 · T.J.S. Mining, Inc.

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Thomas J Smith
Operator
T.J.S. Mining, Inc.
Mine
3609159

Narrative

An unplanned roof fall occurred in the No. 3 entry of 1 Right Room at Survey Station No. 639. Roof fall was approximately 19' wide, 45' long, and 4' plus high. Area was bolted with 4' tension rebar bolts according to the approved Roof Control Plan. Did not affect any equipment, ventilation or travelway. Area was timbered and dangered off.