An unplanned roof fall occurred in the No. 3 entry of 1 Right Room at Survey Station No. 639. Roof fall was approximately 19' wide, 45' long, and 4' plus high. Area was bolted with 4' tension rebar bolts according to the approved Roof Control Plan. Did not affect any equipment, ventilation or travelway. Area was timbered and dangered off.