An unintentional roof fall occured in the #8 return entry outby unit 2. The fall occured do to the strata breaking at and below the anchor point. The area will be propped off. An inspection of all adjoining areas for adverse conditions will be conducted. The fall measured 20' x 20' x 4'. The fall area was located at 9+10 survey station.