# FALL OF ROOF OR BACK
> MSHA accident `220071500011` · 05/18/2007 · T.J.S. Mining, Inc.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Thomas J  Smith
- **Operator:** T.J.S. Mining, Inc.
- **Mine:** [3609159](https://api.ai-analytics.org/mine/3609159)
## Narrative

An unplanned roof fall occurred in the #4 entry - 2nd intersection inby the mine opening.  Fall was approximately 11 feet high, 19 feet wide and 38 feet long.  Area was bolted with 5 foot fully grouted resin bolts along with 6 foot tension re-bar bolts and 10 foot cable bolts.  Fall was on intake escapeway so fall was cleaned up.

---