A roof fall was observed during the preshift exam in the crosscut between #9 & #10 entry @ 10+33. The area was a sump that was cut after mining. The intersection on both ends was cable bolted w/passive cable bolts & cribbed. The fall was approx 70'l x 12'h x 17'w.