In 14th West Pillar section in the #5 entry a roof fall occurred at approximately 12:45 pm. It fell 18' wide x 31' long x 6' high. 5' resin bolts were installed during development. The cave buried two Mobile Roof Supports. There were no injuries. Two MSHA inspectors had been in the section observing mining prior to the fall.