220071630021 · 05/31/2007 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
4200079

Narrative

In 14th West Pillar section in the #5 entry a roof fall occurred at approximately 12:45 pm. It fell 18' wide x 31' long x 6' high. 5' resin bolts were installed during development. The cave buried two Mobile Roof Supports. There were no injuries. Two MSHA inspectors had been in the section observing mining prior to the fall.