← MSHA accidents

HOISTING

220071650042 · 06/06/2007 · Monterey Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Exxon Mobil Corp
Operator
Monterey Coal Company
Mine
1100726

Narrative

Main Portal Elevator not working - doors not opening. Electrial problem; replaced coil and still not working. Replaced L3 leveling switch and L3 relay coil. Adjusted magnetic switch valve. Tested elevator and put back in service at 7:50 a.m. on 6/7/07.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown