# ELECTRICAL
> MSHA accident `220071730056` · 06/19/2007 · ICG Beckley LLC
## Details
- **Degree of injury:** NO DYS AWY FRM WRK,NO RSTR ACT
- **Classification:** ELECTRICAL
- **Accident type:** Contact with electrical current
- **Occupation:** Bull gang foreman, Labor foreman, Leadman, Section foreman, Shift boss
- **Activity:** Electrical maintenance
- **Injury source:** ELECTRICAL APPARATUS,NEC
- **Nature of injury:** ELECTRIC BURN-CNTACT BURN
- **Body part:** HAND (NOT WRIST OR FINGERS)
- **Days lost:** 0
- **Mine experience:** 0.46 years
## Operator
- **Controller:** International Coal Group Inc (ICG)
- **Operator:** ICG Beckley LLC
- **Mine:** [4605252](https://api.ai-analytics.org/mine/4605252)
## Narrative

Employee was attempting to change batteries using jumpers when the power lead came loose from the lug and grounded against the plug housing causing burns to his right hand. He was treated and released to do a follow-up visit on 6/20/07.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*