A roof fall occured in the 1 main east, crosscut #111, starting in the right pillar line of the #4 entry and ending in the left pillar line of the #6 entry. The fall measured approximately 90'x19'x6'-7'. The area was supported with 6' tension rebar bolts and 9' double lock mega bolts.