# FALL OF ROOF OR BACK
> MSHA accident `220071830025` · 06/28/2007 · South Central Coal Company, Inc.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CraKol Energy LLC
- **Operator:** South Central Coal Company, Inc.
- **Mine:** [3401787](https://api.ai-analytics.org/mine/3401787)
## Narrative

A roof fall in the intake airway that is not used for travel or is not an escapway and is in the 1st Left panel mined around 1998 with 6' full grout resin bolts. The fall was in the #3 entry x-cut 10-11 and was 20'x50' long 3-6' thick. Area will not be cleaned up, just dangered and cribbed.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*