A roof fall occurred in the 2 east in the intersection of crosscut #11 in #5 entry and extending through the pillar line between #5 & #6 entry. The fall measured approximately 50' x 19' x 6'. The area was supported with 5' fully grouted bolts and 9' megabolts.