A roof fall was observed approximately 17 X outby the working section in #6 entry at survey station 434. The fall measured approximately 35 feet long, 20 feet wide and approximately 1 foot to 5 feet high. Four foot fully grouted bolts were used in the area. Additional supports (cribs & timber) were being set in the entries to the left prior to the fall.