On 8/3/07, an unintentional roof fall was found at cross cut #13 in #8 entry on the 2nd West sub main, off the 3rd South sub main. The fall was approximately 20' long X 24' Wide X 20' high. The roof was bolted with 10' point anchor bolts. The fall will be cleaned up.