An unplanned roof fall occurred in the #5 entry of 1 Right Mains at survey station #682. Fall was approximately 19' wide, 25' long, 4' plus high. Area was bolted with 4' tension rebar bolts with 6 rows across per our approved Roof Control Plan. Did not affect any travelways, ventilation or equipment. Area was timbered and dangered off.