# FALL OF ROOF OR BACK
> MSHA accident `220072220038` · 07/23/2007 · CONSOL of Kentucky Inc.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** CONSOL of Kentucky Inc.
- **Mine:** [4608892](https://api.ai-analytics.org/mine/4608892)
## Narrative

An unintentional roof fall was discovered in the #7 entry at #27 break (Intake). Size of fall was estimated to be 55'L x 20'W x 6'H. The area had been supported with 4' fully grouted resin bolts with additional support consisting of 10' cable bolts. No injuries, no equipment caught, ventilation was not interrupted. Fall will not be cleaned up.

---