# FALL OF ROOF OR BACK
> MSHA accident `220072220040` · 07/23/2007 · CONSOL of Kentucky Inc.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** CONSOL of Kentucky Inc.
- **Mine:** [4608892](https://api.ai-analytics.org/mine/4608892)
## Narrative

An unintentional roof fall was discovered in the #9 entry at #29 break (Intake). Size of fall was estimated to be 30'L x 20'W x 5'H. The area had been supported with 4' resin bolts. No injuries, no equipment caught, ventilation was not interrupted. Fall will not be cleaned up.

---