- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Cargill Inc
- **Operator:** Cargill Salt 
- **Mine:** [3000663](https://api.ai-analytics.org/mine/3000663)
## Narrative

Hoist kicked out, was reset and then kicked out two more times.  MSHA advised of ""difficulty."" Discovered through trouble shooting a blown resistor.  Changed resistor at 2:25, hoist OK, test trip OK, called MSHA to inform of situation.

---