A coal mill explosion occurred within our coal mill. No injuries of plant personnel. Contributing factors were a diff. of about 20F between control room thermocouple and manual readings. Operational set point for coal mill exit temp. is about 180F and with this diff. there was the possibility that the temp reached 200F.