Troubleshooting the hydraulic adjustment system on the crusher. Installed a pressure gauge on the pump by attaching the pressure hose to a malleable black iron tee that had the pressure gauge threaded in the other end. Pump was turned on and hydraulic pressure split the tee that was in his hand. The hydraulic fluid, under 4000 psi, cut his thumb and damaged a tendon.