The roof fall was discovered in the bleeder entries of the 002-0 Section during a weekly examination of those. The fall measured approx 20' wide X 50' long X 6' thick and fell between crosscuts. The fall is located approx 20' inby S.S. #4068 in the #6 Entry and is approx 3500' from the active section.