# FALL OF ROOF OR BACK
> MSHA accident `220072350037` · 08/15/2007 · Alex Energy Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:** Alex Energy Inc
- **Mine:** [4608787](https://api.ai-analytics.org/mine/4608787)
## Narrative

An unintentional roof fall occurred on 8/15/07. The fall happened on four belt, break #11 in the left return on spad #1377. The fall measured approx 100' long X 20' wide X 6' high. The area was dangered off.

---