A roof fall occurred on the main north track, outby the 24 east track south at 193+00 feet @ 4 entry. The fall was 20 ft wide, 25 ft long and 6 ft high. The fall occurred due to the deterioration of the immediate roof around existing bolts. Area was mined in June 1997. Moisture in air caused deterioration between roof bolts and ribline.