# ELECTRICAL
> MSHA accident `220072470079` · 08/25/2007 · Dominion Coal Corporation
## Details
- **Degree of injury:** DAYS AWAY FROM WORK ONLY
- **Classification:** ELECTRICAL
- **Accident type:** Contact with electrical current
- **Occupation:** Utility man, Errand boy, Service truck operator
- **Activity:** Conveyor belt
- **Injury source:** CONDCTR,ELCT,CBL,TROL POL
- **Nature of injury:** ELECT SHOCK,ELECTROCUTION
- **Body part:** BODY SYSTEMS
- **Days lost:** 10
- **Mine experience:** 0.02 years
## Operator
- **Controller:** Sunoco, Inc.
- **Operator:** Dominion Coal Corporation
- **Mine:** [4406759](https://api.ai-analytics.org/mine/4406759)
## Narrative

Tramming feeder to surface, employee got hold of cable splice and came in contact with 480 A.C. power.

---