An unplanned roof fall occurred in the #2 entry of 2 Left, 2 x-cuts inby survey station #325. Fall was approximately 19' wide, 24' long, and 4' plus high. Area was bolted with 4' tension re-bar bolts with 5 rows across per the approved Roof Control Plan. Area was timbered and dangered off. This did affect the travelway.