# FALL OF ROOF OR BACK
> MSHA accident `220072530036` · 08/30/2007 · West Virginia Mine Power, Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** John B  Preece
- **Operator:** West Virginia Mine Power, Inc
- **Mine:** [4608522](https://api.ai-analytics.org/mine/4608522)
## Narrative

During a weekly airway examination a roof fall was discovered approximately 40 feet inby spad no. 967. The fall measured 40 ft X 20 ft and above the anchor zone using 48 inch double lock roof bolts. The fall is 12 cross cuts outby the face. The fall area was supported and dangered off on all approaches. The fall will not be cleaned up.

---