← MSHA accidents

FALL OF ROOF OR BACK

220072530039 · 08/30/2007 · West Virginia Mine Power, Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
John B Preece
Operator
West Virginia Mine Power, Inc
Mine
4608522

Narrative

During a weekly airway examination a roof fall was discovered in #4 entry 30 feet inby spad # 937 and extended 30 feet inby spad # 951. The fall is 20 feet wide approximately 40 feet long and 5 feet to 6 feet high. It is located approximately 20 cross-cuts outby the face and will not be cleaned up. Approaches are timbered and dangered off.

Source

Authoritative
MSHA Open Government Data
Machine