A fall occurred in the 2nd south, #2 entry, 2800 ft station. The fall was 20' long, 20' wide & 8' high. The area was bolted with 6' & 8' pt anchor bolts. The fall did not affect ventilation, cause injury, block travel or damage equipment. No one is required to travel or work in this entry.