Unintentional roof fall discovered 9/10/07. Located at 8 block, 4 zone, #7 entry, 1 block inby station 3561. Area previously supported with 6 foot full grout resin bolt. Fall measured approximately 20'WX8'HX8'L. Area was developed on or about 01/31/2005.